Adapters Request Portal

instrument: Erytra Eflexis

A fully automated, medium-sized analyzer for performing pretransfusion compatibility tests using DG Gel technology. Erytra Eflexis is the natural evolution in Grifols scalable blood typing solutions.

  • Lucas Galdino
  • Jan 16 2023
  • Sent for field validation
  • Attach files
  • Paola Maita Gonzalez commented
    February 28, 2024 08:21

    Hello Lucas,

    I proposed an alternative way for this connection via email.

    Thanks,

    Paola

  • Paola Maita Gonzalez commented
    February 26, 2024 09:55

    Lucas,

    More questions:

    • purple: are the differents segments avaliated in blood groups. --> What do you mean with this?

    • DGW11E.gru^3SCREEN.pln --> Is it all a test code? There are 2 components here. Are both components test codes?

    Thanks

  • Paola Maita Gonzalez commented
    February 26, 2024 08:15

    Hello Lucas,

    Thanks for your replies.

    1) O|1|QCS117011170715||^^^DGW11E.gru^3SCREEN.pln|20170706105041||||||||||||||||||REPORT^000^ERY|F| --> Is the bold text name of default template of erytra instrument or the test code? You defined the same piece of information in two different ways.

    2) I understand the traces are generated with the ASTM simulator. My concern here is that they look pretty different from the manual, like M and C extra segments, or the O segment containing information in the O-2, while in the manual there's nothing. Can you double check the traces, please?

    Paola

  • Lucas Galdino commented
    February 26, 2024 00:40

    Hi Paola, about your questions:
    1) Is it possible to get information about the definition of these segments. Should the green highligh be considered three different results?
    Yes, can be considered three different results.
    What information is the yellow, purple and red segments?
    yellow: name of default template of erytra instrument.
    purple: are the differents segments avaliated in blood groups.
    red: is a run profile, was send REPORT^000^ERY because the instrument was forwarding an existing result.

    2) The traces contain several segments that are totally absent from the manual description (see red-highlighted) and the instrument name does not match the erytra (yellow).
    Are these traces right?

    Yes, the traces attached was extracted directly from instrument using ASTM HOST SIMULATOR.
    Can you ask the vendor what should be consider as the test code in the O segment?
    Yes. Considering example below:
    O|1|QCS117011170715||^^^DGW11E.gru^3SCREEN.pln|20170706105041||||||||||||||||||REPORT^000^ERY|F|
    You can considered as test code: DGW11E.gru^3SCREEN.pln

    Thanks,
    Lucas Galdino

  • Lucas Galdino commented
    November 24, 2023 13:20

    Dear all,

    I connected in customer enviroment and used a ASMT simulator to received traces from instrument.

    I attached the file.

  • Paola Maita Gonzalez commented
    October 18, 2023 15:38

    Hi Marcus,

    Thanks for the update.

    Best regards,

    Sara Julian

  • Guest commented
    October 17, 2023 17:55

    Hi Paola!

    I requested the extraction of the traces to the local support team, because the instrument is located in the Porto Velho city, very far from the Roche office (3000 kilometers).

    I'm monitoring this request to send it to you as soon as possible.

  • Paola Maita Gonzalez commented
    October 13, 2023 09:16

    Hi Marcus,

    Would it be possible to extract at least real traces from the instrument for all the workflows to support? In this way, internally the team can analyse if with that information it would be feasible to develop the driver.
    Thanks!

  • Guest commented
    October 10, 2023 13:36

    Hello Paola! I hope you are well!

    We tried to receive a new interface manual through our consumer. They contacted the instrument supplier, but obtained the same manual. We reported that it was incomplete, without success.

    Is there anything we can help find in the document? Some information?

    Thank you very much for your attention!

  • Guest commented
    October 10, 2023 13:35
    Hello Paola! I hope you are well!
    We tried to receive a new interface manual through our consumer. They contacted the instrument supplier, but obtained the same manual. We reported that it was incomplete, without success.
    Is there anything we can help find in the document? Some information?
    Thank you very much for your attention!
  • Paola Maita Gonzalez commented
    August 31, 2023 09:36

    Hello Lucas,

    Do you have any update about this manual?

    Thanks

  • Paola Maita Gonzalez commented
    January 19, 2023 08:34

    Hello Lucas,

    Thanks for reaching out.

    Unfortunately, the manual attached does not have the field defined for each message segment. Is it possible for you to get a new document for this instrument where we can find this information?

    Also, we have seen some screenshots in the manual that look like real traces. However, we'd like to have some examples.

    Is it possible for you to get us both pieces of information before 25-JAN-2022?

    Please share this information via email.

    Regards,

    Paola